国产午夜不卡片免费视频_中文精品久久久久国产_99久热这里精品免费_肥熟妇女bbw视频

15562228838(微信同號)13963221227(微信同號)
GDX-105 固定污染源中氯乙烯測定輔助填充柱
您所在的位置:首頁 > 產品展示 > 填充柱

GDX-105 固定污染源中氯乙烯測定輔助填充柱

如果你感興趣的話,可以電話:0632-5667636

產品名稱:GDX-105 固定污染源中氯乙烯測定輔助填充柱

產品型號:GDX-105

產品廠商:浩瀚色譜(山東)應用技術開發(fā)有限公司

簡單介紹

固定污染源中氯乙烯測定輔助填充柱,芝麻香白酒,3-甲硫基丙醇,室內空氣,焦爐煤氣,煉廠氣,天然氣,變壓器油,多氯聯苯,植物油,增塑劑,塑化劑,過氧化物,氨水,氨氣,乙縮醛

GDX-105 固定污染源中氯乙烯測定輔助填充柱的詳細介紹

固定污染源中氯乙烯測定輔助填充柱
固定污染源中氯乙烯測定輔助填充柱 詳細信息:

名稱:填充柱
規(guī)格:1.2m*3mm
粒度:80-100目
材質:不銹鋼/玻璃
應用:HJ T34-1999固定污染源排氣中氯乙烯的測定 氣相色譜法

針對固定污染源排氣中氯乙烯和丙烯醛進行測定,浩瀚色譜(山東)應用技術開發(fā)有限公司建立采用針筒采樣、手動進樣、GDX-105填充柱分離、FID檢測器進行檢測的方法。目標化合物峰形對稱、分離度好,與其它干擾的化合物有較好的分離。氯乙烯和丙烯醛檢出限為0.132 mg/m3和0.120 mg/m3,滿足固定污染源排氣監(jiān)測要求,并在1~200 mg/m3范圍內可以進行準確測定。對配制標氣和用空氣模擬的實際樣品的測定,RSD均在5%以內。通過保存時間對濃度影響的研究,推薦采樣24 h完成分析。

固定污染源中氯乙烯測定輔助填充柱  測試譜圖:



Auxiliary packed column for determination of vinyl chloride in stationary pollution sources
Auxiliary Packed Column for Determination of Vinyl Chloride in Stationary Pollution Source Details:

Name: Packed Column
Specifications: 1.2m*3mm
Granularity: 80-100 mesh
Material: Stainless Steel/Glass
Application: HJ T34-1999 Determination of vinyl chloride in exhaust gas from stationary pollution sources by gas chromatography

For the determination of vinyl chloride and acrolein in the exhaust gas of stationary pollution sources, Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. established a method of using syringe sampling, manual injection, GDX-105 packed column separation, and FID detector for detection. The peak shape of the target compound was symmetrical, the resolution was good, and it was well separated from other interfering compounds. The detection limits of vinyl chloride and acrolein were 0.132 mg/m3 and 0.120 mg/m3, which met the requirements for monitoring the exhaust gas of stationary pollution sources, and could be accurately measured within the range of 1 to 200 mg/m3. For the determination of the prepared standard gas and the actual sample simulated by air, the RSD is within 5%. Through the study of the effect of storage time on the concentration, it is recommended to sample for 24 hours to complete the analysis.

Auxiliary packed column for determination of vinyl chloride in stationary pollution sources Test chromatogram: 


相關產品

HH-TXCH4 耐水的甲烷填充柱應用PE580測定固定污染源廢氣中CH
耐水的甲烷填充柱應用PE580測定固定污染源廢氣中CH4,室內空氣,非甲烷總烴,液化石油氣,二甲醚,甲縮醛,乙縮醛,乙醇,變壓器油,多氯聯苯,植物油,6號溶劑殘留,變壓器油溶解氣,醫(yī)療器械,三甲胺
Haohan-790Deoxidizer 脫氧裝置安裝安PE氣相色譜儀測工業(yè)氫
脫氧裝置安裝安PE氣相色譜儀測工業(yè)氫中氧氬,植物油,6號溶劑殘留,脂肪酸,乙酸乙酯,環(huán)氧乙烷,醫(yī)療器械,粗苯,焦爐煤氣,煉廠氣,天然氣,三甲胺,甲胺,乙胺,雜醇油,蒸餾酒,甲醇,甲酸
20%OV-101/Gas Chrom Q,, 水果中二硫代氨基甲酸酯殘留檢驗
水果中二硫代氨基甲酸酯殘留檢驗賽默飛玻璃柱,非甲烷總烴,液化石油氣,頂空進樣器,粗苯,三苯,二甲醚,植物油,藥典,二氧化碳,甲醛,甲酸,乙酸
GDX-102,, 化妝品中甲醇測定測定填充柱應用安捷倫7890
化妝品中甲醇測定測定填充柱應用安捷倫7890,非甲烷總烴,液化石油氣,頂空進樣器,粗苯,三苯,二甲醚,植物油,藥典,二氧化碳,甲醛,甲酸,乙酸
1m*3mm,, TDX-01填充柱應用在安捷倫/島津/賽默飛
TDX-01填充柱應用在安捷倫/島津/賽默飛,島津,非甲烷總烴,液化石油氣,頂空進樣器,粗苯,三苯,二甲醚,植物油,藥典,二氧化碳,甲醛,甲酸,乙酸
HH-silica gel,, 硅膠填充柱應用島津GC2014測定甲烷乙烯乙
硅膠填充柱應用島津GC2014測定甲烷乙烯乙烷,島津,非甲烷總烴,液化石油氣,頂空進樣器,粗苯,三苯,二甲醚,植物油,藥典,二氧化碳,甲醛,甲酸,乙酸

在線留言

主題 *
內容 *
公司名
聯系人 *
聯系電話 *
電子郵箱
QQ
阿里旺旺
驗證問題 * 1+4等于多少?答案:5
 
儀器交易網
8
推薦收藏該企業(yè)網站