国产午夜不卡片免费视频_中文精品久久久久国产_99久热这里精品免费_肥熟妇女bbw视频

15562228838(微信同號)13963221227(微信同號)
15%DC-550/Chromosorb W AW填充柱 飲用水中三氯甲烷和四氯化碳的頂空氣相色譜測定
您所在的位置:首頁 > 產(chǎn)品展示 > 填充柱

15%DC-550/Chromosorb W AW填充柱 飲用水中三氯甲烷和四氯化碳的頂空氣相色譜測定

如果你感興趣的話,可以電話:0632-5667636

產(chǎn)品名稱:15%DC-550/Chromosorb W AW填充柱 飲用水中三氯甲烷和四氯化碳的頂空氣相色譜測定

產(chǎn)品型號:15%DC-550/Chromosorb W AW填充柱

產(chǎn)品廠商:浩瀚色譜(山東)應用技術開發(fā)有限公司

簡單介紹

15%DC-550/Chromosorb W AW填充柱,飲用水中三氯甲烷和四氯化碳的頂空氣相色譜測定,植物油,增塑劑,塑化劑,過氧化物,三甲胺,二甲醚,乙縮醛,乙醇,室內(nèi)空氣,焦爐煤氣

15%DC-550/Chromosorb W AW填充柱 飲用水中三氯甲烷和四氯化碳的頂空氣相色譜測定的詳細介紹

飲用水中三氯甲烷和四氯化碳的頂空氣相色譜測定
飲用水中三氯甲烷和四氯化碳的頂空氣相色譜測定 詳細信息:

名稱:島津Shimadzu填充柱


型號:15%DC-550/Chromosorb W AW填充柱


規(guī)格:2m*3mm


使用溫度:220°C


應用:《生活飲用水衛(wèi)生標準》(GB/T5749-2006)


柱效高,分離好,結(jié)果滿意。




浩瀚色譜(山東)應用技術開發(fā)有限公司建立測定飲用水中三氯甲烷和四氯化碳含量的頂空15%DC-550/Chromosorb W AW填充柱氣相色譜法,同時考察不同來源飲用水中氯仿和四氯化碳的分布狀況.方法 采用頂空自動進樣技術.用特異性15%DC-550/Chromosorb W AW填充柱氣相色譜法測定水中三氯甲烷和四氯化碳.結(jié)果 標準曲線的相關系數(shù)為>0.999,相對標準偏差為1.5%~8.3%,三氯甲烷、四氯化碳的平均回收率為97.5%~103.3%;三氯甲烷的線性范圍為2.0~10.0μg/L,檢出限為0.02μg/L;四氯化碳線性范圍為1.0~5.0μg/L,檢出限為0.003μg/L.結(jié)論 該方法簡便、快速,具有較好的精密度與準確度,可用于水中三氯甲烷、四氯化碳的測定.


飲用水中三氯甲烷和四氯化碳的頂空氣相色譜測定  測試譜圖:




Determination of chloroform and carbon tetrachloride in drinking water by headspace gas chromatography
Headspace Gas Chromatographic Determination of Chloroform and Carbon Tetrachloride in Drinking Water Details:

Name: Shimadzu packed column



Model: 15%DC-550/Chromosorb W AW packed column



Specifications: 2m*3mm



Operating temperature: 220°C



Application: "Sanitation Standard for Drinking Water" (GB/T5749-2006)



The column efficiency is high, the separation is good, and the results are satisfactory.




Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. established a headspace 15%DC-550/Chromosorb W AW packed column gas chromatography method for the determination of chloroform and carbon tetrachloride in drinking water, and at the same time investigated chloroform in drinking water from different sources The distribution of chloroform and carbon tetrachloride in water. The method adopts headspace automatic sampling technology. Determination of chloroform and carbon tetrachloride in water by specific 15%DC-550/Chromosorb W AW packed column gas chromatography. Results of standard curve The correlation coefficient was >0.999, the relative standard deviation was 1.5%~8.3%, the average recoveries of chloroform and carbon tetrachloride were 97.5%~103.3%; The output limit is 0.02μg/L; the linear range of carbon tetrachloride is 1.0~5.0μg/L, and the detection limit is 0.003μg/L. Conclusion The method is simple, rapid, has good precision and accuracy, and can be used for Determination of chloroform and carbon tetrachloride in water.


Headspace gas chromatographic determination of chloroform and carbon tetrachloride in drinking water Test spectrum:

相關產(chǎn)品

6m*3MM,, GDX-105填充柱應用在賽默飛1300上
GDX-105填充柱應用在賽默飛1300上,非甲烷總烴,液化石油氣,頂空進樣器,粗苯,三苯,二甲醚,植物油,藥典,二氧化碳,甲醛,甲酸,乙酸
2m*4MM,, GDX-102填充柱應用在島津GC2030
GDX-102填充柱應用在島津GC2030,非甲烷總烴,液化石油氣,頂空進樣器,粗苯,三苯,二甲醚,植物油,藥典,二氧化碳,甲醛,甲酸,乙酸
2m*1/8,, GDX-101填充柱應用賽默飛1300
GDX-101填充柱應用賽默飛1300,非甲烷總烴,液化石油氣,頂空進樣器,粗苯,三苯,二甲醚,植物油,藥典,二氧化碳,甲醛,甲酸,乙酸
2m*1/8,, TDX-01填充柱應用島津GC2030
TDX-01填充柱應用島津GC2030,非甲烷總烴,液化石油氣,頂空進樣器,粗苯,三苯,二甲醚,植物油,藥典,二氧化碳,甲醛,甲酸,乙酸
3m*1/8,, Molecular Sieve 13X填充柱應用安捷倫島津
Molecular Sieve 13X填充柱應用安捷倫島津,非甲烷總烴,液化石油氣,頂空進樣器,粗苯,三苯,二甲醚,植物油,藥典,二氧化碳,甲醛,甲酸,乙酸
甲烷轉(zhuǎn)化爐HH-790CH4-GC,, 發(fā)酵(真空)物體里面的二氧化碳
發(fā)酵(真空)物體里面的二氧化碳和甲烷測定,便攜式甲烷轉(zhuǎn)化爐,一氧化碳,甲烷,二氧化碳,高純氣體,H2,O2,N2,Ar,CO,CO2,CH4

在線留言

主題 *
內(nèi)容 *
公司名
聯(lián)系人 *
聯(lián)系電話 *
電子郵箱
QQ
阿里旺旺
驗證問題 * 2*0等于多少?答案:0
 
儀器交易網(wǎng)
8
推薦收藏該企業(yè)網(wǎng)站